MODEL | HM7KW Pro | HM8KW | HM10KW | |||||
TECHNICAL | ||||||||
BATTERY |
Rated voltage | 48V/96Vdc | 60/96Vdc | |||||
Charging voltage | 13.8V/27.6V/55.2V | 27.6V/55.2V/110V | ||||||
Charging current | 10~25A | |||||||
Charging voltage | 55.2Vdc for 48Vdc (*5 for 60Vdc; *8 for 48V, *8 for 96Vdc) battery | |||||||
Battery high voltage alarm | 60Vdc for 12Vdc (*5 for 48Vdc, *8 for 96Vdc) battery | |||||||
Battery low voltage alarm | 42Vdc for 12Vdc (*5 for 48Vdc, *8 for 96Vdc) battery | |||||||
Battery type | Lithium / gel battery (factory default) | |||||||
GRID INPUT |
Voltage | L+N+PE, 220V/230V/240Vac | ||||||
Voltage range | 75~135Vac for 110Vac grid; 145-265Vac for 220Vac grid | |||||||
Frequency | 50/60Hz (auto-sensing) | |||||||
PV INPUT |
MPPT optimal voltage | 48V: 60~150Vdc; 60V: 80~220Vdc; 96V: 120~220Vdc | ||||||
MPPT working voltage range | 18~150Vdc for 12V/24V/48V; 120~180Vdc for 96V | |||||||
Charging current | MPPT 60A/100A | |||||||
Maximum PV array power | For 60A MPPT: 48V/3200W, 60V/4800W, 96V/6000W | |||||||
For 100A MPPT: 48V/5000W, 60V/6000W, 96V/10000W | ||||||||
Maximum PV array voltage | For 48V: 155Vdc; for 60V: 225Vdc; for 96V: 226Vdc | |||||||
OUTPUT |
Voltage | L+N+PE, 110V/120V; 220V/230V/240Vac | ||||||
Frequency | 50/60Hz ±1% (auto-adaptation) | |||||||
Surge power | 9kVA | 12kVA | 15kVA | 18kVA | 21kVA | |||
Efficiency | 89% | 90% | 89% | |||||
Waveform | Pure sine wave | |||||||
Protection | Overvoltage, under voltage, overload, over temperature, surge, short circuit | |||||||
Display | LCD+LED | |||||||
Heat dissipation mode | Fan | |||||||
Communication (optional) | RS232/RS485/App/Wi-Fi | |||||||
WORKING MODE | Grid prior | Working priority is given to grid power, and transfers to battery inverter when grid is abnormal | ||||||
Eco mode | The device automatically goes into sleep mode when the load is empty | |||||||
PV prior | PV first, and when PV is not sufficient, battery and grid complement each other | |||||||
Environmental |
Humidity | 0%~95% relative humidity (non-condensing) | ||||||
Operating temperature | -10 ~ 50°C | |||||||
Storage temperature | -15 ~ 60°C | |||||||
PHYSICA. | Dimension (D*W*H) (mm) | 650x380x800 | ||||||
Net weight | 55 | 63 | 72 |