MODEL | BNT 500 | BNT 1000 | BNT 1500 | BNT 2000 | BNT 3000 | BNT 3500 | BNT 5000 |
Rated power | 500W | 1000W | 1500W | 2000W | 3000W | 3500W | 50000W |
DC voltage | 12/24V | 12/24V | 24/48V | 24/48V | 48V | 48V | 96V |
LINE INPUT | |||||||
Phase | L + N + G | ||||||
Input voltage | 115 ~ 275 Vac | ||||||
Input frequency | 40 ~ 60 Hz | ||||||
Input protection | Fast fuse | ||||||
INVERTER OUTPUT | |||||||
Output voltage | 110 / 220 / 230 / 240 Vac ±5% | ||||||
Output frequency | 50/60Hz ± 1% | ||||||
Output supply | Single phase | ||||||
Output frequency | Synchronized to utility power | ||||||
Working efficiency | ≥80% | ||||||
Waveform | Pure sine wave, THD < 4% at full load | ||||||
Transfer time | ≤2ms | ||||||
Overload capacity | 120% for 30 seconds; 150% for 10 seconds | ||||||
SOLAR INPUT | |||||||
Max. voltage | 21V | 42V | 84V | 168V | |||
Charge current | 20A | 20/30A | 20-40A | 20-60A | |||
Over charge protective voltage | 14.2V | 28.4V | 57.2V | 114.4V | |||
Over charge recovery voltage | 13.7V | 27.4V | 54.8V | 109.6V | |||
Constant charge voltage | 13.5V | 27V | 54V | 108V | |||
Over discharge alarm voltage | 10.5V | 21V | 42V | 84V | |||
Voltage drop | ≤0.3V between solar module and battery, ≤0.15V between load and battery | ||||||
Start speed of cooling fan | 55 degrees centigrate | ||||||
BATTERY | |||||||
Charge current | 20A | 20/30/40/60A optional | |||||
Float charge voltage | 13.75 ±0.5Vdc per 12Vdc battery | ||||||
Over discharge | After over discharge protection shutdown, the battery discharge current is less than 10uA | ||||||
Protection | Anti-charge at night, battery over charge/over discharge protection, joint-reverse protection of solar modules | ||||||
SYSTEM & ENVIRONMENTAL | |||||||
City main fault alarm | When city main is interrupt, there will be 6 times continuous alarm, and then stop alarm | ||||||
Control mode | PWM | ||||||
Battery alarm | When the battery voltage is close to shutdown point, the alarm sound from slow to fast until the inverter shuts down | ||||||
Display | City main working voltage, output voltage, working frequency, load status, battery capacity | ||||||
Communication | RS 232 + USB, RJ45 / RJ11 (optional) | ||||||
Noise level | ≤45dB (1 meter from surface) | ||||||
Operating temperature | 0°C to +40°C (32°F to 104°F) | ||||||
Humidity | 0%-90% (non-condensing) | ||||||
Altitude | 1000m | ||||||
Enclosure protection rating | IP20 | ||||||
PHYSICAL | |||||||
Dimensions (HxWxD) (mm) | 330x220x130 | 395x150x210 | 420x201x320 | 450x220x570 | |||
Package size (HxWxD) (mm) | 398x276x214 | 466x201x276 | 481x238x376 | 540x290x630 | |||
Net weight (kg) | 7 | 8 | 9 | 15 | 16 | 20 | 45 |
Weight (kg) | 7.5 | 8.5 | 9.5 | 16.5 | 17.5 | 26 | 60 |