MODEL | BNG 300 | BNG 500 | BNG 1000 | BNG 1200 | BNG 1500 |
Power rating | 300W | 500W | 1000W | 1200W | 1500W |
Battery voltage | 12/24Vdc | 12/24/48Vdc | |||
Working mode | PV prior or AC prior optional | ||||
PV INPUT | |||||
Input max. voltage | 21V | ||||
Rated power | 250Wp | 500Wp | |||
Max. charge current | 20A | ||||
Max. transfer efficiency | 90 - 96% (DC to AC transfer efficiency) | ||||
MPPT function | User option | ||||
AC INPUT | |||||
Input voltage range | 165-275Vac | ||||
Input frequency range | 50/60Hz | ||||
Charge current | 20A | 40A | |||
BATTERY | |||||
Over charge protective voltage | 14.2Vdc | ||||
Over charge recovery voltage | 13.8Vdc | ||||
Constant charge voltage | 13.5Vdc | ||||
Over discharge alarm voltage | 10.2Vdc | ||||
Battery charge mode | PWM, 8A direct charge, turns into float charge when battery capacity reaches 90% | ||||
AC OUTPUT | |||||
Output voltage range | 100/110/120/220Vac ±3% | ||||
Output frequency | 50/60Hz ±0.5Hz | ||||
Output waveform | Pure sine wave | ||||
Overload capacity | overload 120% or short circuit automatically shut off the inverter, 1 seconds after automatic restart the inverter | ||||
Efficiency | 92% - 97% at linear load | ||||
No load current | <8W | ||||
Power factor (cosØ) | 1 | ||||
No load off (optional) | Load < 5% after 1 minute, transfer to bypass mode | ||||
Short circuit | System shut down automatically | ||||
Total harmonic current distortion (THD) | < 3% for linear load, < 5% for nonlinear load, all of them in full load condition | ||||
Dynamic response time | 5ms typical value, max. 8ms | ||||
SYSTEM FEATURES | |||||
Type of cooling | Temperature control forced ventilation | ||||
Start speed of cooling fan | 65°C | ||||
Voltage drop between solar module and battery | ≤0.15V | ||||
LED indicator | solar panel (green), battery normal (yellow), battery failure(red), power start (green/yellow), inverter normal (yellow), line normal (green) | ||||
Protection function | output overload and short circuit, battery low voltage and over charging protection, solar panel Polarity reverse connect protection, overheating protection, lightning protection | ||||
Alarm | sounding every 25 seconds at battery low voltage | ||||
ENVIRONMENTAL | |||||
Electric net control | according to UL1741, According to IEEE-2000 standard | ||||
Electromagnetism | according to EN61000-3-2 | ||||
Utility grid test | according to DIN VDE 126 | ||||
Operating temperature | -10°C to +60°C | ||||
Storage temperature | -30°C to +70°C | ||||
Humidity | 0-95% (non-condensing) | ||||
Altitude | 2000m (Every 100m increase de-rates 1%) | ||||
Noise level | < 10dBA | ||||
Enclosure protection rating | IP55 | ||||
Communication port (optional) | RS232/RS485/USB/SNMP | ||||
PHYSICAL | |||||
Dimensions (HxWxD) (mm) | 200x100x50 | 240x160x70 | 320x160x70 | 450x250x113 | |
Weight (kg) | 0.6 | 1 | 2.8 | 4.5 | 4.9 |