• 3500W off-Grid Solar Inverter with 48V/30A Controller
  • 3500W off-Grid Solar Inverter with 48V/30A Controller
  • 3500W off-Grid Solar Inverter with 48V/30A Controller
  • 3500W off-Grid Solar Inverter with 48V/30A Controller
  • 3500W off-Grid Solar Inverter with 48V/30A Controller
  • 3500W off-Grid Solar Inverter with 48V/30A Controller

3500W off-Grid Solar Inverter with 48V/30A Controller

After-sales Service: 1 Year Warranty
Warranty: 1 Year Warranty
Certification: CE
Application: Home, Industrial, Commercial
Specification: Normal, CE
Weight: 40kg
Samples:
US$ 499/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory
Gold Member Since 2014

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (23)

Basic Info.

Model NO.
BNT-35014830
Phase
L + N + G
Grid High Voltage Protection
275VAC ±5%
Input Frequency
40 ~ 65Hz
Charging Current
0~15A
Battery Type
Maintenance-Free Lead Acid Battery, or Gel Battery
Battery Voltage Range
20~30VDC Per 24VDC Battery Voltage
Max. Voltage
21V Per 12V Battery Voltage
Output Voltage
110/220/230/240VAC ±5%
Waveform
Pure Sine Wave, Thd ≤ 3% at Full Load
Transfer Time
< 4ms
Transport Package
Export Wood Case
Trademark
Bosin or OEM
Origin
Shenzhen
HS Code
8504403090
Production Capacity
50000units/ Month

Product Description

BNT 500W - 5kW
 
Solar Inverter / Controller

BNT series solar inverter/controller is a classic pure sine wave solar generator which is consists of solar controller and solar inverter.

Solar controller is an important part of solar power system. It could intelligently control and protect system charge, discharge and loading status. Its quality and performance directly affects the reliability of the solar power system, especially the lifespan of the battery. Overcharge and over discharge could cause damage to the battery or even cause fire.

Solar off-grid inverter converts DC power from solar panels into AC. BNT adopts low frequency transformer based design with strong loading capability. The inbuilt AVR function enables a wide input voltage range. It outputs pure sine wave power, is capable of supporting all kinds of loads with full protections against overload, short circuit, low battery voltage, surge, and lighting, etc.
 
3500W off-Grid Solar Inverter with 48V/30A Controller
3500W off-Grid Solar Inverter with 48V/30A Controller




Salient Features

Wide input voltage range at 110 - 270V, wide frequency range at 38 - 65Hz
PV prior or city mains prior optional
Multi-functional output, AC, 12V LED, or 5V USB charging sockets
Compatible with both linear and non-linear load
Low heat dissipation in long time operation
Low energy loss with idle current less than 0.8A
Pure sine wave output (THD<3% at linear load)
LCD/LED display shows key operation status
Temperature sensor controlled cooling fan
The real short-circuit protection

Range of application:

Mobile phone charging, laptops power suply, TV sets, Air conditioner, Refrigerator, Professional tools, instruments, small home solar power system.
 
MODEL BNT 500 BNT 1000 BNT 1500 BNT 2000 BNT 3000 BNT 3500 BNT 5000
Rated power 500W 1000W 1500W 2000W 3000W 3500W 50000W
DC voltage 12/24V 12/24V 24/48V 24/48V 48V 48V 96V
LINE INPUT
Phase L + N + G
Input voltage 115 ~ 275 Vac
Input frequency 40 ~ 60 Hz
Input protection Fast fuse
INVERTER OUTPUT
Output voltage 110 / 220 / 230 / 240 Vac ±5%
Output frequency 50/60Hz  ± 1%
Output supply Single phase
Output frequency Synchronized to utility power
Working efficiency ≥80%
Waveform Pure sine wave, THD < 4% at full load
Transfer time ≤2ms
Overload capacity 120% for 30 seconds; 150% for 10 seconds
SOLAR  INPUT
Max. voltage 21V 42V 84V 168V
Charge current 20A 20/30A 20-40A 20-60A
Over charge protective voltage 14.2V 28.4V 57.2V 114.4V
Over charge recovery voltage 13.7V 27.4V 54.8V 109.6V
Constant charge voltage 13.5V 27V 54V 108V
Over discharge alarm voltage 10.5V 21V 42V 84V
Voltage drop ≤0.3V between solar module and battery, ≤0.15V between load and battery
Start speed of cooling fan 55 degrees centigrate
BATTERY
Charge current 20A 20/30/40/60A optional
Float charge voltage 13.75 ±0.5Vdc per 12Vdc battery
Over discharge After over discharge protection shutdown, the battery discharge current is less than 10uA
Protection Anti-charge at night, battery over charge/over discharge protection, joint-reverse protection of solar modules
SYSTEM & ENVIRONMENTAL
City main fault alarm When city main is interrupt, there will be 6 times continuous alarm, and then stop alarm
Control mode PWM
Battery alarm When the battery voltage is close to shutdown point, the alarm sound from slow to fast until the inverter shuts down
Display City main working voltage, output voltage, working frequency, load status, battery capacity
Communication RS 232 + USB, RJ45 / RJ11 (optional)
Noise level ≤45dB  (1 meter from surface)
Operating temperature 0°C to +40°C (32°F to 104°F)
Humidity 0%-90% (non-condensing)
Altitude 1000m
Enclosure protection rating IP20
PHYSICAL
Dimensions (HxWxD) (mm) 330x220x130 395x150x210 420x201x320 450x220x570
Package size (HxWxD) (mm) 398x276x214 466x201x276 481x238x376 540x290x630
Net weight (kg) 7 8 9 15 16 20 45
Weight (kg) 7.5 8.5 9.5 16.5 17.5 26 60

3500W off-Grid Solar Inverter with 48V/30A Controller3500W off-Grid Solar Inverter with 48V/30A Controller3500W off-Grid Solar Inverter with 48V/30A Controller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001